The solar radiation shield is usually used for outdoor temperature, temperature+humidity and weather station.  The sheild can protect sensing elements from sun, ran and snow. The water-proof shield is made of qualitive anti-ultraviolet materials,thus it can protect the built-in sensors from being affected by precipitation and solar radiation.

The solar radiation shield can measure temperature, humidity, atmospheric pressure, light Lux, CO2, PM2.5,PM10,noise,concentration of O2,NH3,H2S,etc. Users can select related parameters as requirement, and the parameters value can be readou by one-wire RS485 Modbus-RTU.

The solar shield weather station utilizes high-sensitivity digital probes to ensure stable signal and good accuracy. The product has features of wide measurement range, good linearity, good water-proof, easy using, convenient to install,long communication distance,etc. With the water-proof shiled, product can suitable for various of applications, and have been widely in city environment, agriculture monitoring, industrial treatment,etc.

For the solar radiation, we have improved its sealing by adding several designs. This improvement can effectively prevent rain and snow from entering the shutter box through the gaps, avoid corrosion to circuit board. The working life and stability of solar radiation measurement have been ensured.

Temperature+Humidity:

  • Temp.Range: -40℃ - +120℃
  • Humidity Range: 0%-99%RH
  • Temp. Accuracy:±0.5℃ (25℃)
  • Humidity Accuracy:±3%RH(25℃)
  • Power Supply: 10-30VDC
  • Output:RS485(Modbus)
  • Response Time:<15S(1m/s)
  • Long-term stability:Temp.<=0.1; Humidity<=1%RH

CO2 Parameter:

  • Measuring Range: 0-5000ppm
  • Accuracy: ± (40ppm+3%F.S.) (at 25℃)
  • Working Temp.: -20 -60℃
  • Working Humidity: 0%-80%RH
  • Power Supply: 10-30VDC
  • Output: RS485(Modbus)
  • Response Time: <=1S
  • Long-term Stability: 0.1KPa/y
  • Pre-heating time: 2min(available);10min(Max accuracy)

Light Lux Parameter:

  • Measuring Range: 0-200,000LUX
  • Accuracy: ± 7% (at 25℃)
  • Working Temp.: -20 -60℃
  • Working Humidity: 0%-80%RH
  • Power Supply: 10-30VDC
  • Output: RS485(Modbus)
  • Response Time: 0.1S
  • Long-term Stability:<=5%/y

Other Parameter Optional:

  • CH4,O3,O2,H2,NH3
  • HCHO, H2S,CO,CO2, SO2

 Color Version Optional,Decorate Your View

Barometer Parameter:

  • Measuring Range: 0-120KPa
  • Accuracy: ± 1.5KPa(at 25℃)
  • Working Temp.: -20 -60℃
  • Working Humidity: 0%-80%RH
  • Power Supply: 10-30VDC
  • Output: RS485(Modbus)
  • Response Time: <=1S
  • Long-term Stability: 0.1KPa/y

Noise Parameter:

  • Measuring Range: 30dB-120dB
  • Accuracy: ± 3dB
  • Frequency Weighting: A Class
  • Frequency Range:20Hz-12.5KHz
  • Working Temp.: -20 -60℃
  • Working Humidity: 0%-80%RH
  • Power Supply: 10-30VDC
  • Output: RS485(Modbus)
  • Response Time: <=3S
  • Long-term Stability: <2% during using period

PM2.5/PM10 Parameter:

  • Measuring Range: 0-1000ug/m3
  • Resolution: 1ug/m3
  • Accuracy: ± 10% (at 25℃)
  • Working Temp.: -20 -60℃
  • Working Humidity: 0%-80%RH
  • Power Supply: 10-30VDC
  • Output: RS485(Modbus)
  • Response Time: 90S
  • Pre-heating time: 2min

NOTE:

  • For a solar radiation shield house, CO2 and PM2.5/PM2.0 can select one.